There are four steps involved in the fit testing process:
choosing the respirator, fit checking, taste threshold (sensitivity) screening,
and the fit test. A company should provide various sizes from different brands to
have available for selection for their employees. People have a variety of face
and head sizes so there must be different types available for them to select
which one is most comfortable. Before an employee can decide which one is most
comfortable the company must first show them how to properly put the respirator
on, including the position of the face piece on the chin and around the bridge
of the nose. Once the employee has chosen a proper respirator they should next
be taught how to perform positive and negative fit checks.
A fit check makes sure that the respirator properly fits the
employees face and that no air is getting into the mask. There are two types of
tests, positive pressure and negative pressure. This fit test should be
completed every time the respirator is worn. A positive pressure test is when the
user breathes out, which exerts a positive pressure on the respirator. On the
other hand, a negative pressure check is when the user breathes air in, which
exerts a negative pressure on the respirator. To perform these tests the user
will properly put the respirator on and then they must cover the surface of the
respirator completely. The entire respirator acts as a filter and this is why
the entire thing must be covered. The easiest way to do this is to cover the
respirator with a sheet of plastic.
To complete the positive pressure test the user should
breathe out gently and feel around the respirator to see if air is escaping
from the face piece. If the user does not feel air escaping around the face
piece, they have passed the positive fit check. However, if they feel air
escaping around the face piece, the respirator should be repositioned and
perform the fit check until a positive result is achieved.
To complete a negative pressure fit check the user should
inhale, thus creating a vacuum which causes the respirator to be drawn in
slightly toward the face. If this does not occur then the test has failed and
the respirator should be removed and examined for any holes or a problem with
the seal. If neither is found then the respirator should be repositioned and
the test should be re-performed until it results in a positive result.
The next step in fit testing is the taste threshold screen
test. A dilute solution is used to determine if the wearer can detect the
substance while wearing the respirator. Two substances that could be used are:
saccharine (sweet taste), or bitrex (bitter taste.)
The fit test is finally performed after completing the above
procedures. The subject should wear the respirator for at least five minutes
before the fit test. The test subject should perform the following exercises
for at least 30 seconds each, while the tester continues to squeeze the correct
amount every thirty seconds: · Normal breathing · Deep breathing · Turning head
from side to side, inhaling at both sides · Nodding head up and down, inhaling
in both up and down positions · Bending forward to touch toes, inhaling when
head is down · Talking (Ask the subject to read a paragraph aloud, such as The Rainbow
Passage, or ask them to tell you a story, etc.) · End by resuming normal
breathing.
This is the rainbow passage:
When the sunlight strikes raindrops in the air, they act
like a prism and form a rainbow. The rainbow is a division of white light into
many beautiful colors. These take the shape of a long arch, with its path high
above, and its two ends apparently beyond the horizon. There is, according to
legend, a boiling pot of gold at one end. People look, but no one ever finds
it. When a man looks for something beyond his reach, his friends say he is
looking for the pot of gold at the end of the rainbow.
http://www.aphl.org/aphlprograms/infectious/tuberculosis/TB-Core-Curriculum/Documents/FitTestProcedure.pdf
No comments:
Post a Comment
Note: Only a member of this blog may post a comment.